Ther-Monic SST Series Induction Power Supply

Thyristor Based Solid State AC-DC-AC Converters

Thyristor-Based Solid State
AC-DC-AC Converters

The SST Series Induction Power Supply

S o l i d  S t a t e , T h y r i s t o r

  • All Solid State Design: Small size and weight, Microprocessor controlled.
  • Coil matching network includes isolation transformer and series capacitor bank for efficient power transfer.
  • Easy set-up, Low maintenance, No warm-up with instant on.
  • Push-button controlled for easy operator interface, repeat accuracy of +/- 0.5% of setting.
  • Operator push-button for on/off and potentiometer for converter power control.
  • Diagnostic indicating lights for either fault or warning conditions:
  • Over-current protection
  • Over-voltage protection
  • Unique load sensor current
  • Electronic water flow switch
  • Power Supply internal temperature protection
  • RF/EMI input filter
  • Transient over-voltage and surge current protection
  • Electrically isolated low voltage output transformer
  • Fast fuse on output circuit
  • Fast input circuit breaker
  • Tracks temperature by means of a 4-20 mA control input.
  • Universal input jack provides direct interface with PLC.
  • Optional Accessories: Water-to-air Heat Exchangers, Foot Pedal, and Process Automation Machinery.

 

Power Supply Specifications

 
Medium Frequency (25-50 KHz) Power Supplies
  Power Required Incoming Diminsions (inches) Weight
Model (watts) Cooling Line Width Depth Height (pounds)
SST
1.5B
15002 Water3
0.25 GPM

115 V
6,7

12 10.5 6.38 20
SST
2.5R
25002 Water3
0.4 GPM
230 V
6,9
13.5 7.25 14.5 32
SST
5.0R
50002 Water3
0.7 GPM
230 V
6,11
15.5 8.25 17.5 55

Notes:

  1. Specifications are subject to change without notice. Our policy is continuous improvement
  2. Power output dependent on load quality.  Full power delivered to a majority of loads.
  3. Recommended pressure differentional 40 psi (30 psi minimum, 100 psi maximum)
      1. Maximum inlet temperature 40 degrees centigrade (104 degrees Fahrenheit).
      2. Resistivity 2200 ohm/cm maximum (mineral free)
  4. Other voltages available on special order basis.
  5. 115v +/- 10% 50/60 Hz, 1 phase, 12.5 amperes, 0.6 P.F., 2.5 KVA.
  6. 230v +/- 10% 50/60 Hz, 1 phase, 11.0 amperes, 0.6 P.F., 4.1 KVA.
  7. 230v +/- 10% 50/60 Hz, 1 phase, 22.0 amperes, 0.6 P.F., 8.3 KVA. 230V, 3 phase also available