All Solid State Design: MOSFET inverter with unusally high KVA series resonant output circuit. Single or three phase diode bridge input drives the MOSFET inverter output.
Compact size, convenient bench-style design.
Standard Features: Transformer isolation, flexible load tuning/matching via tapped series inductor, MOSFET transistor modules, and adjustable capacitance.
Coil matching network includes tuning inductor and series capacitor bank for efficient power transfer. Radio frequency switching supply designed to automatically track the load
resonant frequency.
Push-Button Controls: For easy operator interface, repeat accuracy of +/- 0.1% of setting. Electronic Keying.
Operator Interface Panel: Numeric display of power supply output volts, inverter current, output frequency & kilowatts, and system performance diagnostics.
Numeric Display for total heat time (auto and manual mode), job number (auto only), program step number (auto only), and step time duration (auto only).
Heat ON/OFF Controls and Emergency Stop Push-Button.
Protection Features with diagnostic indicating lights for either fault or warning conditions.
Over-current protection
Over-voltage protection
Grounded secondary output transformer
Line circuit breaker, manual operation, with under voltage release
Power Supply internal temperature switch
Key locked panels
Fuses
Electronic keying
Power Supply water flow switch
Additional fault connections (user defiined for increased diagnostics)
Optional Accessories: Water-to-air Heat Exchangers, Water Chiller, Process Automation Machinery.
SPECIFICATIONS
Output KW
Model Number
Input Power Supply
Output Voltage Frequency
Dimensions HxWxD Wt.
Water Cooling
12.5
MMF-12.5-35-100-2 MMF-12.5-135-400-2
208-240 V. 3~ 50/60Hz. 37 A. @ 230 V. 14.5 kVA14.5 kVA
350 V rms 35-100 kHz. 500 V rms 135-400 kHz.
36 x 20 x 15 145 lb.
2 GPM min. @ 100 psi max. 30 psi minimum diff. pressure. 105° F. max inlet temperature.
25
MMF-25-35-100-2 MMF-25-135-400-2
208-240V. 3~ 50/60 Hz. 73 Amperes @ 230 V. 29 kVA
350 Vrms 35- 100 kHz. 500 Vrms 135-400 kHz.
36 x 20 x 15 185 lb.
4 GPM min. @ 100 psi max. 30 psi minimum diff. pressure. 105° F. max inlet temperature.
40
MMF-40-35-100-2 MMF-40-135-400-2
440-480V. 3~50/60 Hz. 56 Amperes @ 480 V. 46 kVA
350 Vrms 35- 100 kHz. 500 Vrms 135-400 kHz.
36 x 20 x 15 185 lb.
6 GPM min. @ 100 psi max. 30 psi minimum diff. pressure. 105° F. max inlet temperature.
100
MMF-100-135-400-1
440-480V. 3~ 50/60 Hz 144 Amperes @ 480 V 120 kVA
1000 Vrms 135-400 kHz.
62" x 24" x 34" 420 lb.
16 GPM min. @ 100 psi max. 30 psi minimum diff. pressure. 105° F. max inlet temperature.