Information - Email us at sales@taylor-winfield.com
 

Ther-Monic

The MMF Series Induction Power Supply

M O S F E T,   M u l t i      F r e q u e n c y

  • All Solid State Design:  MOSFET inverter with unusally high KVA series resonant output circuit. Single or three phase diode bridge input drives the MOSFET inverter output. Compact size, convenient bench-style design.
     
  • Standard Features: Transformer isolation, flexible load tuning/matching via tapped series inductor, MOSFET transistor modules, and adjustable capacitance.
     
  • Coil matching network includes tuning inductor and series capacitor bank for efficient power transfer. Radio frequency switching supply designed to automatically track the load resonant frequency.
     
  • Push-Button Controls:  For easy operator interface, repeat accuracy of +/- 0.1% of setting. Electronic Keying.
     
  • Operator Interface Panel:  Numeric display of power supply output volts, inverter current, output frequency & kilowatts, and system performance diagnostics.
     
  • Numeric Display for total heat time (auto and manual mode), job number (auto only), program step number (auto only), and step time duration (auto only).
     
  • Heat ON/OFF Controls and Emergency Stop Push-Button.
     
  • Protection Features with diagnostic indicating lights for either fault or warning conditions.
  • Over-current protection
  • Over-voltage protection
  • Grounded secondary output transformer
  • Line circuit breaker, manual operation, with under voltage release
  • Power Supply internal temperature switch
  • Key locked panels
  • Fuses
  • Electronic keying
  • Power Supply water flow switch
  • Additional fault connections
           (user defiined for increased diagnostics)     
  • Optional Accessories:  Water-to-air Heat Exchangers, Water Chiller, Process Automation Machinery.

SPECIFICATIONS

Output
KW

Model Number

Input Power Supply

Output
Voltage    Frequency

Dimensions
H”xW”xD” Wt.

Water Cooling

12.5

MMF-12.5-35-100-2
MMF-12.5-135-400-2

208-240 V. 3~ 50/60Hz.
37 A. @ 230 V.
14.5 kVA14.5 kVA

350 V rms      35-100 kHz.
500 V rms    135-400 kHz
.

36” x  20” x 15” 145 lb.

2 GPM min. @ 100 psi max.
30 psi minimum diff. pressure. 105°
 F. max inlet temperature.

25

MMF-25-35-100-2
MMF-25-135-400-2

208-240V. 3~ 50/60 Hz.
73 Amperes @ 230 V.
29 kV
A

350 Vrms     35- 100 kHz.
500 Vrms     135-400 kHz.

36” x  20” x 15” 185 lb.

4 GPM min. @ 100 psi max.
30 psi minimum diff. pressure. 105° F. max inlet temperature
.

40

MMF-40-35-100-2
MMF-40-135-400-2

440-480V. 3~50/60 Hz.
56 Amperes @ 480 V.
46 kV
A

350 Vrms     35- 100 kHz.
500 Vrms     135-400 kHz
.

36” x 20” x 15” 185 lb.

6 GPM min. @ 100 psi max.
30 psi minimum diff. pressure. 105° F. max inlet temperature.

100

MMF-100-135-400-1

440-480V. 3~ 50/60 Hz
144 Amperes @ 480 V
120 kVA

1000 Vrms  135-400 kHz.

62" x 24" x  34" 420 lb.

16 GPM min. @ 100 psi max.
30 psi minimum diff. pressure. 105° F. max inlet temperature
.

HOME