2” Cylinder:250Lbs. at 80PSI max. air pressure 3 1/4” Cylinder:650Lbs. at 80PSI max. air pressure
Weights
Welder - 210 Lbs. Transformer - 150 Lbs. Control - Vaires with manufacturer
ELECTRICAL SPECIFICATIONS
Transformer, Dual Voltage 230/460 @ 50/60Hz.
L2 0.75-6-230/460
KVA Rating
7.5
Secondary Cables
600 MCM 16” CFF Term.
Secondary Volts
5.97 Max. 2.99 Min.
Secondary Amps., S.C. +/- 10%
12,300 Max. 1,100 Min.
KVA Demand, S.C. Max. +/- 20%
73.4
Primary Amps, Max.
230 Volts: 319 460 Volts: 159
Fusible Line Switch Rating, Amps
230 Volts: 60 460 Volts: 30
Line Fuse Rating, Amps
230 Volts: 60 460 Volts: 30
Recommended Cable Size for Runs up to 100 ft.
230 Volts: #4 AWG 460 Volts: #8 AWG
Although Taylor-Winfield recommends the indicated fusible isolation switches and cable sizes, check local, city and state electrical code requirements.