Specifications for EBB-3 Spot/Projection Welders
MECHANICAL SPECIFICATIONS

Throat Depth to Centerline of Ram

8”

Welding Force in Pounds:

Stamdard Regulator

Precision Regulator

at 80 PSI

2” Dia. Cylinder
3” Dia. Cylinder
4” Dia. Cylinder

62 to 250
185 to 565
251 to 1000

35 to 250
70 to 565
125 to 1000

Ram Stroke

1.75

1.25” x 2” Lower Horn Vertical Adjustment

4”

1” Dia. Lower Electrode Holder

Type:

Ejector

Water Cooled

Length:

6”

 

RWMA Taper No:

4 or 5

Upper Electrode Holder

Type:

Ejector or Screw

Water Cooled

RWMA Taper No:

4 or 5

Electrodes, Upper and Lower

Length:

1.5”

Other Lengths Available

RWMA Taper No:

4 or 5

ELECTRICAL SPECIFICATIONS

These welding machines operate on single phase AC, 230 or 460 Volts, 60 Cycles (only one voltage - specify which:) other voltages and frequencies available on request.

EBB3

Rating is based on 60 Cycles, 50% duty cycle

 

10KVA

20KVA

30KVa

40KVA

Secondary Volts:

Max. Parallel
Min. Parallel
Max. Series
Min. Series

3.15
1.81
1.79
1.26

5.22
3.07
2.95
2.11

6.21
3.33
3.33
2.30

7.93
4.79
4.42
3.24

Secondary Amps. S.C.:

Max. Parallel +/-10%
Min. Parallel +/-10%
Max. Series +/-10%
Min. Series +/-10%

13,600

7,800

7,700

5,400

23,000

13,500

13,000

9,300

27,000

14,900

14,900

10,300

35,300

21,400

19,700

14,500

Demand KVA S.C.:

Max. Parallel

43

120

172

275

Duty Cycle, S.C.:

Max. Parallel %

2.7

1.4

1.5

1.7

Power Factor S.C. %

 

51

51

49

49

Primary Amps.

Max. 230Volts
Max. 460Volts

186
93

523
260

748
374

1217
608

SCR Contacter Size, Amperes

230Volts
460Volts

300
300

300
600

600
600

600
600

Circuit Breaker Amperes

230Volts
460Volts

100
100

100
100

100
100

225
100

Line Fuse Rating, Amperes:

230Volts
460Volts

50*
35*

100**
50*

100**
50*

150**
100**

 

 

 

 

 

 

Cable Size 5% Drop, 5% Duty Cycle

 

 

 

 

 

Cable Runs not over 100 Ft. Cables in Contact

230Volts

1

1

000

444 MCM

90o C. Hypalon or Equal

460Volts

8

6

4

2

* The Taylor-Winfield Corporation recommends Buss Fuse type LPN or LPS
** The Taylor -Winfield Corporation recommends Gould Shawmut Fuse type A4BX

CONTROL OPERATING VOLTAGE will be the same as welder power supply unless otherwise specified. Initiating switch voltage is 24, and solenoid valve voltage is 115.

TRANSFORMER SECONDARY VOLTAGES and other electrical characteristics will be furnished as shown above, unless otherwise specified.

THE TAYLOR-WINFIELD CORPORATION recommends the above indicated fusible isolation switches and cable sizes, but purchaser should check local and state electrical code requirements.

Short circuit current measurements are taken at 3" spacing between top of lower horn and bottom of upper electrode holder using electrodes in the welder.
 