MECHANICAL SPECIFICATIONS

Machine Type

 

Style 1

Style 2

Horn Size

Inches, Upper
Inches, Lower

--

2.5 Sq.
2.5 Sq.

Horn Adjustment

Inches, In
Inches, Out

--

0
1

Platen Spacing, Inches

Head Up-Knee Up
Head Up-Knee Down

9
15

9
15

Horn Spacing, Inches

Head Up-Knee Up
Head Up-Knee Down

--

4
10

Standard Operating Cylinder

Diameter, In

4”

6”

Maximum Force, Lbs.

 

1075

2335

Minimum Force, Lbs.

With Standard Air Regulator
With Precision Air Regulator

175

300

Platen Dimensions

Inches

6” Sq. T-Slots on 3.5” Centers

Electrode Holders

Upper
Lower

1.250” Dia. Barrel, 8” Long
1.250” Dia. Barrel, 12” Long

Electrodes

 

RWMA B-2508, Class 2 Alloy 2” Long, No. 5 Taper

Cylinder Stroke, Standard *

Inches

5

Air Pressure Required PSI

 

80

Free Air Consumption**

(4” Cylinder)

.09

Cubic feet per inch of stroke

(6” Cylinder)

.21

* Working stroke approx. .25" less than cylinder stroke for electrode wear.
** Maximum at 80 psi - operating cylinder only.

ELECTRICAL SPECIFICATIONS

 

Throad Depth, Inches

 

12*

18*

18**

24**

 

Secondary Volts, Maximum

 

7.93

7.93

7.93

7.93

 

Current Output, Amperes, Maximum*****

 

51,900

42,500

34,000

29,100

50KVA

Power Demand, KVA, Maximum*****

 

411

337

270

230

RATING

Power Factor, Short Circuit, %

 

31

35

35

28

60Hz

Duty Cycle at Above KVA Demand, %

 

.7

1.1

1.7

2.36

 

Primary Amperes at Maximum Demand*****

460V.
230V.

890
1790

732
1465

586
1172

502
1004

-----------

----------------------------------------------------------

----------

-----------

-----------

----------

-----------

 

Secondary Volts, Maximum

 

9.58

9.58

9.58

9.58

 

Current Output, Amperes, Maximum*****

 

58,800

48,400

40,900

35,000

100KVA

Power Demand, KVA, Maximum*****

 

563

464

391

335

RATING

Power Factor, Short Circuit, %

 

31

35

35

28

60Hz

Duty Cycle at Above KVA Demand, %

 

1.6

2.3

3.27

4.4

 

Primary Amperes at Maximum Demand*****

460V.
239V.

1225
2450

1008
2016

852
1704

729
1458

POWER SUPPLY REQUIREMENTS

Power supply requirements are listed for estimating purposes only. Purchaser should check state and local codes and be governed accordingly.

Transformer Rating at 50% Duty Cycle, 60Hz

50KVA

100KVA

Power Supply Primary Voltage

230

460

230

460

SCR Contacter Size 100% Continuous Rating

600A

600A

1200A

1200A

Circuit Breaker Size, Amps

225

100

400

225

Isolation Switch Size, Amps.

200

100

400

200

Fuse Size, Amps.

150***

100***

300***

150***

Cable Size, 100Ft Run, 5% Drop, 5% Duty Cycle, 90o C. Hypalon or equal

500
MCM

2

2-4/0 Per Leg

3/0

* Measured as a projection welder, Style 1.
** Measured as a spot welder, Style 1A.
*** The Taylor-Winfield Corporation recommends Buss fuse type LPN or LPS.
**** Short circuit values (plus or minus 10%) measured at 8" platen spacing with 2-1/2"                                  square copper shorting bar on centerline of platen of projection welders, and at 8" horn       spacing and copper shorting bar substituted for electrode holders in spot welders.

Control operating voltage will be same as welder power supply unless otherwise specified. Solenoid valve voltage will be 115 volts
 