Machine Type
|
EBT 30KVA
|
EBT 50KVA
|
EBMT 75KVA
|
EBMT 100KVA
|
|
Actual Throat Depth
|
2.5”
|
2.5”
|
2.5”
|
2.5”
|
|
Weld Force Range1: Max. @ 80 PSI
Min. @ 80 PSI
|
500 Lbs. 65 Lbs.
|
925 Lbs. 115 Lbs.
|
1,600 Lbs. 200 Lbs.
|
2,800 Lbs. 360 Lbs.
|
|
Platen Size2
|
3.75 x 4”
|
3.75 x 4
|
4” x 4”
|
4” x 4”
|
|
Air Cylinder Stroke
|
2.5”
|
2.5”
|
3”
|
3”
|
|
Shipping Weight3
|
1.050
|
1,150
|
1,800
|
2.000
|
|
 |
|
|
|
Rating is based on 60 cycles, 50% duty cycle
|
30KVA
|
50KVA
|
|
Secondary Volts Max. Parallel
Min. Parallel Max. Series
Min. Series
|
6.22 3.40 3.12 2.19
|
7.96 4.80 4.52 4.88
|
|
Secondary Amps, S.C. Max. Parallel +/- 10%
Min. Parallel +/- 10% Max. Series +/- 10%
Min. Series +/- 10%
|
40,000 22,000 19,900 14,100
|
51,900 30,900 29,400 21,500
|
|
Demand KVA, S. C. Max. Parallel
|
251
|
413
|
|
Duty Cycle, S.C. Max. Parallel, Percent
|
.71
|
.73
|
|
Power Factor, Percent
|
62
|
62
|
|
Primary Amps, Max. 230 Volts
460 Volts 550 Volts
|
1092 546 459
|
1790 895 752
|
|
Electronic Power Tube Size for 230, 460 or 550 Volt
|
A
|
B
|
|
SCR Contactor Size for 230, 460 or 550 Volt
|
600 Amp
|
600 Amp
|
|
Fusible Line Disconnect Switch Rating for: 230 Volt
460 or 550 Volt
|
200 100
|
400 200
|
|
Line Fuse Rating, Amperes 230 Volts
460 Volts 550 Volts
|
170 90 80
|
280 150 120
|
|
Cable Size 5% Drop, 5%Duty Cycle for Cable Run not over 100ft., Cables in Contact:
230 Volts 460 Volts
550 Volts
|
4/0 4 4
|
2-4/0 2 2
|
|
 |
|
|
|
Rating is based on 60 cycles, 50% duty cycle
|
75KVA
|
100KVA
|
|
Secondary Volts Max. Parallel
Min. Series
|
9.58 3.33
|
10.95 4.03
|
|
Secondary Amps, S.C. Max. Parallel +/- 10%
Min. Series +/- 10%
|
68,000 25,500
|
96,000 35,300
|
|
Demand KVA, S. C. Max. Parallel
|
650
|
1050
|
|
Duty Cycle, S.C. Max. Parallel, Percent
|
.66
|
.45
|
|
Power Factor, Percent
|
47
|
47
|
|
Primary Amps, Max. 230 Volts
460 Volts
|
2826 1413
|
4568 2284
|
|
Electronic Power Tube Size for 230, 460 or 550 Volt
|
C
|
C
|
|
SCR Contactor Size 230 Volt
460 Volt
|
2700 Amp 1800 Amp
|
2700 Amp 1800 Amp
|
|
Fusible Line Disconnect Switch Rating for: 230 Volt
460 Volt
|
600 400
|
800** 400
|
|
Line Fuse Rating, Amperes 230 Volts
460 Volts
|
450 250
|
800** 400
|
|
Cable Size 5% Drop, 5%Duty Cycle for Cable Run not over 100ft., Cables in Contact:
230 Volts
460 Volts
|
(2) 4/0 3/0
|
(3) 535 MCM* 777 MCM*
|
|
 |
 |
|
* Due to heavy power demand and large cables required, 230 volt supply for 75 and 100 KVA machine is not recommended.
** 1,200 Amp circuit breaker with 50,000 Amp interrupting capacity-trip rating 4,500 Amps.
OPERATING CONTROL VOLTAGE AND SOLENOID VALVE VOLTAGE will be 115 volts unless otherwise specified. INITIATION
VOLTAGE will be 24 volts DC unless 115 volts AC is specified. TRANSFORMER SECONDARY VOLTAGES and other electrical characteristics shown above will be furnished unless otherwise specified. LEADS FOR WELDING
POWER supply are provided within the welder frame so that power connections can be made at customer's convenience. Taylor-Winfield recommends the above indicated fusible line disconnect switches and cable sizes, but
customer should check local, city and state electrical code requirements.
|
|