Load against backstops, space bar, or with material butting. Preheat with controlled force and multiple pulses. Linear preflash. High or low voltage start, anti-stall
feature, low voltage flash, high or low voltage upset, selectable automatic anneal. Selectable family of Flash curves. Full digital operation using standard PC's.
12-bit Digital curve generation at 6000 samples/sec. 3-additional 12-bit analog outputs available. Acquire and display 16 analog inputs (+/- volts). Weld schedule, results and date/time saved after each
weld. Data is automatically transferred to Exel spreadsheet. Analyze and save Voltage, Current, and Position waveforms. Real-time position and pressure compensation.
Tensile test and resistivity measurement after weld. HV or LV @ full cycle firing LV flash @ full cycle firing HV or LV Upset + heat control LV Preheat + heat control LV Anneal + heat control
|